Off-grid, RV & cabin
Generator backup hybrid sizing tool
Enter your running load, largest motor, and battery recharge target. Get the smallest generator that reliably covers your gap, not an oversized guess.
How it works
Three steps to a generator size
Step 1
Add up your running load
Total everything that could run at once while the generator is on, including the battery charger itself. This is your baseline running watt requirement.
Step 2
Check your largest motor's surge draw
A fridge compressor or well pump can spike to 2 to 4 times its running wattage for an instant at startup. This surge, not the running load, often sets the true minimum generator size.
Step 3
Set a battery recharge target
Decide how much battery deficit you want the generator able to replace, and how many hours of runtime you're willing to spend doing it. Faster recharge needs more charger wattage.
Understanding generator backup sizing
Why hybrid generator sizing is different from whole-house sizing
A generator paired with solar and battery storage has a narrower job than a standalone backup generator: cover running load, survive motor startup surges, and recharge the battery within a reasonable window. A cabin with 1,200 running watts, a 400-watt fridge compressor, and a target of recharging a 200Ah deficit in 3 hours typically needs a generator in the 2,500 to 3,000 running watt range, well below what a generator sized to run an entire home from scratch would need. Pair this with the whole home backup sizing calculator to see the full picture before you commit.
Surge watts, not running watts, often set the floor
Motors draw far more current at the instant they start than while running steadily. A 400-watt fridge compressor commonly surges to 1,000 to 1,600 watts for a fraction of a second, and a generator that can't cover that surge will stall or trip its breaker even if it handles the running load with room to spare. Always check a generator's starting or surge watt rating against your largest motor's surge draw, not just its running watt rating against your total load. The annual maintenance cost estimator picks up where this leaves off, using the figure you just found.
The generator's real job is recharging the battery
In a hybrid system, the generator usually isn't running your appliances directly most of the time. Instead, it runs a battery charger that refills the bank after a stretch of low sun, then shuts off once the battery is topped up. Sizing the charger draw around a specific recharge window, rather than trickle-charging over many hours, keeps generator runtime and fuel use low. The hybrid generator solar runtime calculator estimates how many hours a year this actually adds up to.
Altitude and heat derate generator output
Gas generators lose roughly 3% to 4% of rated output per 1,000 feet of elevation above sea level, which matters for mountain cabins in Colorado, the Canadian Rockies, or similar high-elevation sites. High ambient heat also reduces output. Add extra margin to the recommended size here if your site sits above 3,000 feet or regularly sees summer heat above 95°F. Ready.gov's power outage preparedness guide covers general backup planning if a generator is your primary resilience plan rather than a solar supplement. Remote systems are easy to neglect. The battery lifespan estimator in our Maintenance & Lifespan section can help you budget for the maintenance that keeps output from slipping.
What to check once you have a generator size
Once you know your target wattage, compare propane and diesel options for ongoing fuel cost, and check the generator fuel cost calculator to estimate your annual backup fuel budget. Fuel cost assumptions draw on EIA's Electric Power Annual report. If this generator is meant to cover a whole cabin rather than just a battery-recharge role, the whole home backup sizing calculator in our battery storage tools handles that larger scope, and the annual maintenance cost estimator in our maintenance and lifespan tools budgets for the generator's own upkeep over time. Even off-grid, the money side matters. The payback period calculator in our Savings & Payback section can help you compare the system cost with the cost of extending the grid.
Questions
Frequently asked
Most solar-backup generators run 2,000 to 3,500 running watts, since the generator only needs to cover running load, motor surge, and battery recharge current rather than the entire daily load alone. A cabin with 1,200 running watts, a 400-watt fridge compressor, and a battery charger drawing 940 watts typically needs about 2,500 to 3,000 running watts with margin.
Motors like fridge compressors, well pumps, and AC units draw 2 to 3 times their running wattage for a fraction of a second at startup, called locked rotor or surge current. A generator sized only for running watts can stall or trip when a motor starts, even if it handles the load fine once running.
In a solar hybrid system, the generator's main job is usually recharging the battery bank during extended cloudy stretches, not running the full load directly. This keeps the generator smaller, quieter, and far more fuel-efficient than sizing it to carry the whole house or cabin alone.
A well-sized solar system with a backup generator commonly runs the generator 50 to 150 hours a year, mostly during winter cloudy stretches or unusually high-load periods, rather than as a daily source of power.