System sizing
Multi-roof plane array splitter
If your roof has more than one usable face, enter each plane's area and see your target system size split across them proportionally, with panel counts for each.
How it works
Three steps to your split
Step 1
Measure each roof plane's usable area
Use the usable roof area calculator for each plane separately, since setbacks and obstructions differ face to face.
Step 2
Split panels proportionally to area
The tool assigns panel counts to each plane in proportion to its share of total usable area, a simple starting point before adjusting for shading or orientation quality. It also checks the target against how many panels the planes can physically hold.
Step 3
Wire each plane on its own string or MPPT
With a string inverter, keep each roof plane on a separate string or MPPT input rather than mixing orientations in one series string. Check the DC to AC ratio calculator once you know each plane's panel count.
Splitting an array across more than one roof face
Why area-proportional splitting is a simple starting point
Assigning panels in proportion to each plane's usable area spreads the target evenly across the roof, so no face is filled harder than another. It is a convenient starting point, not an energy optimum: if the planes face different directions, panels on the best-oriented plane produce more, so filling that plane first usually yields more energy for the same panel count, a trade-off the south-facing vs east-west array calculator quantifies. Installers also adjust for known shading and for a household's usage timing, since an east-west split favors morning and evening generation.
Why each series string needs a single orientation
Panels in a series string pass the same current, so the string runs at the pace of its weakest panel. Mixing orientations inside one string forces the sunnier panels to throttle to match the weaker ones at any given moment. NLR's test of a partially shaded grid-tied string shows how hard that weakest-link behavior can bite: in one configuration a shadow cut power by more than 30 times its own size. The usual fix is one orientation per string, with strings from different planes on separate MPPT inputs, which most residential string inverters provide in pairs or more. Manufacturer testing of true east-west arrays has found small losses when parallel strings share one input, but separate inputs are the safer default. Each input also has its own current limit, so check the inverter datasheet when one plane carries most of the panels.
When a small roof plane needs microinverters instead
A string needs enough panels in series to reach the inverter's minimum operating voltage, often somewhere around 4 to 6 panels depending on the specific inverter model. A roof plane too small to support a dedicated string on its own is a common case where microinverters make more practical sense, since each panel operates independently with no minimum string length to worry about, a tradeoff the microinverter vs string inverter output tool lays out directly.
Shade on one plane is a separate question from the split
Splitting by area says nothing about shade. On a string inverter, a shaded plane drags down its own string while the others keep working, but shade is also where module-level electronics earn their cost. NREL's shading testbed report found a microinverter system produced 3.7% more energy under light shading, 7.8% under moderate shading, and 12.3% under heavy shading than a string inverter on identical 8 kW arrays. If one plane has known shade, the partial roof shading sizing adjustment tool shows how much to adjust before finalizing the split.
Check that each plane can hold its share
This tool caps each plane at what fits at your panel footprint, about 21 square feet per panel by default, and says plainly when the target needs more panels than the planes can hold. Confirm each plane's usable area first with the usable roof area calculator, since setbacks and obstructions differ face to face. Structure is a separate check, and the roof truss load capacity calculator shows whether a plane can carry its assigned panel count.
Questions
Frequently asked
With a standard string inverter, yes, panels facing different directions or tilts should sit on separate strings or MPPT inputs, not mixed into one series string. Most modern residential inverters have at least two MPPT inputs built in for exactly this situation.
Proportional to each plane's usable area is a simple starting point because it spreads the target evenly across the roof. It is not an energy optimum: panels on the best-oriented plane produce more, so adjust for orientation quality, shading, or usage timing, as an east-west split does to favor morning and evening generation.
Yes, most residential string inverters allow unequal string lengths across separate MPPT inputs, as long as each string stays within the inverter's voltage window. Microinverters remove this constraint entirely, since each panel operates independently regardless of how many panels sit on any given roof plane.
Splitting adds design complexity and, with a string inverter, requires enough panels on each string to reach the minimum operating voltage. A roof plane too small to reach that minimum, often around 4 to 6 panels depending on the inverter, may need microinverters instead of a dedicated string.
Related tools