Off grid inverter sizing calculator

Enter your running loads and your largest motor's startup surge. See your total continuous demand, your worst-case surge, and whether a given inverter size covers both.

Your numbers

1 Project details Optional
Shown on your exported report. Leave blank to skip.
2 Running loads
Sum of the running wattage of everything that could be on at once, including the motor load below.
The running watts (not surge watts) of your biggest single motor load, like a well pump or AC compressor.
3 Motor surge
Check the motor's nameplate or datasheet for its actual locked rotor or starting current if available.
Enter a continuous kW rating to see if it covers both your running load and surge.

How it works

Three steps to size your off grid inverter

Step 1

List every load and add up running watts

Include everything that could realistically run at the same time, from lighting and refrigeration to your largest motor load. This total sets your minimum continuous inverter rating. The off grid battery bank sizing calculator covers the related sizing question for this setup.

Step 2

Identify your single largest motor

Well pumps, air conditioner compressors, and workshop tools are common candidates. The inverter sizing for well pump startup tool covers that specific case in more depth.

Step 3

Check a candidate inverter against both figures

A size that covers running load alone might still fall short on surge capability. Enter a candidate size to see both checks side by side, or use the surge capacity calculator for a deeper look at surge behavior alone.

Understanding off grid inverter sizing

Why off grid sizing starts from load, not from the array

Grid tie systems size their inverter around the solar array's output, since the grid absorbs any mismatch. Off grid systems have no such backstop. The inverter has to reliably power the connected loads on its own, which means the starting point is always what needs to run, not what the panels produce. The array and battery bank get sized around that load figure afterward. If you haven't fully committed to going off grid, the grid tie vs off grid comparison tool lays out that broader decision first.

Why motor startup surge catches so many first-time designs off guard

A well pump might draw 750 running watts once it's spinning steadily, but the same motor can briefly pull 2,000 to 3,000 watts at the instant it starts, since an electric motor needs extra current to overcome its own resting inertia. An inverter sized only for running watts can brown out, trip a fault, or fail to start the motor at all when this surge hits. This is the single most common off grid sizing mistake for systems that include any motor-driven equipment, and the same startup physics apply to the inverter sizing for HVAC startup tool as well.

Why only the largest motor's surge usually matters

In most real households, motors don't all start at the exact same moment by coincidence. The realistic worst case is everything else already running steadily while one additional motor, typically the largest, kicks on. Sizing for every motor surging at once would push the inverter far larger than necessary for a scenario that essentially never happens in practice. The Department of Energy's overview of inverter and grid services covers the inverter side of this kind of load planning in more general terms.

Reading a surge rating correctly

Inverter datasheets often list a surge rating alongside the continuous rating, sometimes specified for a duration like 5 seconds or 20 seconds. A 2,000W continuous inverter rated for 4,000W surge for 5 seconds can start a motor that briefly demands up to 4,000W, as long as the motor reaches full running speed within that window. Motors that take longer to spin up, or surge higher than the rated duration allows, need a larger inverter or a soft-start device on the motor itself. The inverter continuous vs peak rating calculator covers this distinction across inverter types more broadly.

Building in room for future loads

Off grid systems in remote areas like rural Montana or Alaska often expand over time as homeowners add workshop tools, larger appliances, or an additional cabin structure. Sizing the inverter with some extra continuous and surge headroom beyond today's exact load list avoids an expensive early upgrade. The inverter sizing for motor loads calculator can help model a broader set of future equipment, and once the inverter is settled, the off grid battery bank sizing calculator is the natural next step for sizing the storage side to match, with SEIA's overview page aimed at solar shoppers as a good starting point if any of this off-grid planning is new territory.

Questions

Frequently asked

Off grid inverter sizing starts with total running load, the sum of everything that could operate at the same time, then checks the startup surge from the largest motor load. A well pump, air conditioner compressor, or similar motor can draw 2 to 4 times its running wattage for a brief moment at startup.

Motors rarely all start at the exact same instant, so the worst-case surge scenario is everything else already running steadily while just one motor, the largest one, experiences a cold start. Sizing for every motor starting simultaneously would overestimate the requirement significantly.

Many off grid inverters can handle roughly twice their continuous rated wattage for a few seconds during a surge event, though this varies by brand and model. Always confirm the exact surge rating and duration in the specific inverter's datasheet rather than assuming a 2x figure.

Off grid systems typically size around a defined, deliberate load list rather than every possible household appliance, since unlimited grid backup isn't available to cover gaps. Being intentional about which loads the system needs to support keeps the inverter, battery bank, and array all reasonably sized together.