Inverters & equipment
Hybrid inverter sizing calculator
Enter your solar array, battery power rating, and backup load. See which one drives your inverter size, and get a recommended standard size.
How it works
Three steps to size your hybrid inverter
Step 1
Get your solar array's AC output
Use the same DC to AC ratio approach as a standard grid tie system. The solar inverter size calculator covers this calculation on its own if you want more detail. The savings with battery vs without battery turns this result into dollars and payback time.
Step 2
Check your battery's continuous power rating
This is different from the battery's total kWh capacity, and it's the number that actually limits how fast the battery can feed the inverter.
Step 3
Total your backup load
Total the circuits you want live during an outage, running at the same time. The transfer switch sizing calculator uses this same backup load figure.
Understanding hybrid inverter sizing
Why a hybrid inverter has three sizing inputs instead of one
A standard grid tie inverter only ever needs to convert solar DC power to AC, so its size follows directly from the array. A hybrid inverter does more jobs at once. It converts solar power, manages battery charging and discharging, and during an outage, it powers backup circuits independently of the grid. Because these three jobs can each demand a different amount of power, the inverter needs to be rated for whichever demand is largest, not just the solar array alone. The Department of Energy's technical overview of grid-connected inverters covers this multi-role behavior in more general terms.
Why backup load sometimes drives the whole design
If a home wants to keep a well pump, HVAC system, and refrigerator running during an outage, that combined backup load can easily exceed what the solar array or battery alone would require. In that scenario, the inverter needs to be sized for the backup load even if it means the inverter runs well under capacity during normal daytime solar production. The inverter sizing for HVAC startup and inverter sizing for well pump startup tools help account for motor startup surges within that backup total.
Battery power rating versus battery capacity
A battery's kWh rating describes how much total energy it stores, like a bucket's size. Its kW power rating describes how fast that energy can flow out, like the width of the bucket's spout. A large battery with a low power rating can still bottleneck a hybrid system, even though it holds plenty of energy overall. Always check both figures separately when sizing, which the battery inverter pairing size calculator handles as a dedicated check once you know your hybrid inverter's own limits.
Watch for combined throughput limits
Some hybrid inverter models cap the combined simultaneous flow of solar input plus battery output, separate from each individual component's own rating. This detail varies significantly between manufacturers and isn't always obvious from headline specs, so it's worth confirming directly in the installation manual for whichever model you're considering, especially for larger systems pushing multiple demands at once.
Planning for future changes
Households in Boise, Idaho or similar regions with occasional winter grid outages often add battery capacity or backup circuits after their initial installation. If that's a realistic possibility, sizing the inverter with some headroom now avoids a costly replacement later. The inverter sizing for future battery addition tool walks through that planning step directly, and the savings with battery vs without battery can help you decide whether that future addition is worth planning for at all. SEIA's consumer-facing explainer on solar systems is a useful starting point if hybrid systems are new territory.
Questions
Frequently asked
A standard grid tie inverter only needs to handle the solar array's AC output. A hybrid inverter needs to be rated for whichever is largest among the solar output, the battery's continuous power rating, and the backup load it needs to power during an outage.
The inverter still needs to be sized for the backup load, since it must be able to power those critical circuits even at night or during low sun, when the battery alone is carrying the load. A 6kW backup load requires at least a 6kW-rated inverter regardless of a smaller solar array.
Continuous power rating is the maximum sustained output a battery can deliver, separate from its total energy capacity in kWh. A battery rated for 5kW continuous power can only feed the inverter at that rate, which can bottleneck the whole system even if the battery holds plenty of energy.
Most installers add 10% to 15% headroom above the calculated requirement to leave room for future load additions and to avoid running the inverter at its absolute ceiling during normal operation, which can shorten component life over time.