Solar inverter size calculator

Enter your array's DC wattage and your target DC to AC ratio. Get a recommended inverter AC size in seconds.

Your numbers

1 Project details Optional
Shown on your exported report. Leave blank to skip.
2 Your array
Most residential panels sold today are 350 to 440 watts.
3 Target ratio
Higher ratios use inverter capacity more fully but clip more output at peak sun.
Real inverters come in fixed sizes, not exact decimals.

How it works

Three steps to an inverter size

Step 1

Find your array's DC size

Multiply your panel count by panel wattage to get your total DC array size. If you already know your panel count from the solar panel calculator, bring that number over directly. The payback period calculator turns this result into dollars and payback time.

Step 2

Pick a target DC to AC ratio

A ratio of 1.20 is a common residential default. Check the inverter oversizing calculator if you want to see how a higher ratio trades off against clipping loss.

Step 3

Round to a real inverter size

Inverters come in fixed model sizes, not exact decimals. Once you have a target size, check the grid tie inverter sizing calculator or hybrid inverter sizing calculator depending on which inverter type you're installing.

Understanding your inverter size

Why the inverter is smaller than the array's rated wattage

An 8,000 watt DC array with a 1.20 ratio needs a 6.67 kW inverter. This is normal, not an error. Panels almost never produce their full rated wattage at once, since that number assumes lab test conditions of 25 degrees Celsius and a specific light spectrum that real rooftops rarely match exactly. Sizing the inverter smaller than the array's rated wattage lets the inverter run closer to its own full capacity more of the time instead of sitting underused for most of the day. This inverter figure is only half the system; the solar panel calculator covers sizing the array that feeds it in the first place.

What a DC to AC ratio actually trades off

A low ratio near 1.10 wastes very little potential output but leaves inverter capacity unused during average conditions. A high ratio near 1.30 uses the inverter more fully but clips a larger share of output during the sunniest hours of the sunniest days. Most manufacturers and installers land between 1.15 and 1.25 for residential systems as a practical middle ground. The inverter clipping loss estimator shows the actual energy lost at your specific ratio. The Department of Energy's technical overview of grid-connected inverters covers these inverter basics in more general terms.

Standard inverter sizes you'll actually find

Residential string inverters commonly come in sizes like 3.8 kW, 5.0 kW, 6.0 kW, 7.6 kW, 10 kW, and 11.4 kW, though exact lineups vary by manufacturer. Once this calculator gives you a target size, round up to the nearest size your preferred brand actually sells rather than assuming a custom size exists. The central inverter vs string inverter cost tool compares pricing across common size tiers.

When your setup needs a different sizing approach

Off grid and hybrid systems size differently than grid tie systems, since battery charging and backup loads factor into the total. If you're not running a straightforward grid tie system, use the off grid inverter sizing calculator or hybrid inverter sizing calculator instead of this general tool for a more accurate number.

What to check before you buy

Beyond total AC wattage, confirm the inverter's MPPT voltage window fits your string design and its maximum input current fits your parallel string count. The MPPT voltage window calculator and parallel strings current calculator check these two limits directly. Once the sizing is settled, the payback period calculator gives a rough sense of what the combined system is worth over time, and NREL's PVWatts calculator offers a more detailed production estimate before you finalize a purchase.

Questions

Frequently asked

Divide your array's total DC wattage by your target DC to AC ratio, usually between 1.1 and 1.3. An 8,000 watt DC array with a 1.20 ratio needs a 6.67 kW inverter, which rounds up to the nearest standard size of 7.6 kW.

The DC to AC ratio compares your panels' rated output to your inverter's rated output. Panels rarely hit their full rated wattage in real conditions, so a ratio above 1.0, typically 1.1 to 1.3, lets the inverter run closer to full capacity more often without wasting inverter capacity on rare peak moments.

A modestly undersized inverter clips a small amount of output during peak sun, which is normal and expected up to a ratio near 1.3. A severely undersized inverter clips too much energy and shortens your system's real annual output well below what the panels could produce.

If you're likely to add panels or a battery within a few years, choosing an inverter with some headroom above your current array size avoids a second inverter purchase later. The inverter sizing for future battery addition tool models this directly.