Off-grid, RV & cabin
System autonomy days calculator
Enter your target autonomy days and panel array. Get a battery size that credits realistic partial solar output during heavy cloud cover, not just zero sun.
How it works
Three steps to a realistic battery size
Step 1
Set your load and target autonomy days
How many days you want the system to survive an extended cloudy stretch.
Step 2
Enter your panel array and cloudy output credit
This is what separates this tool from a pure zero-sun calculation: panels still make some power during heavy overcast, and crediting that reduces the battery you actually need.
Step 3
Compare against the zero-sun equivalent
See exactly how much smaller your realistic battery target is compared to assuming total darkness for the whole outage.
Understanding realistic autonomy sizing
The direct answer for a typical system
For a system with 800 watts of panel and a 2,000Wh daily load targeting 3 days of autonomy, crediting 15% cloudy production reduces the required battery from about 312Ah under a pure zero-sun assumption to roughly 237Ah, a real reduction in both cost and physical space. The panels don't stop working during heavy overcast, they just work at a fraction of their clear-sky output, and that fraction still counts toward covering your load. Current figures live in the National Laboratory of the Rockies Annual Technology Baseline, which updates its residential battery storage cost data each year. Panel wattage means little if the inverter cannot carry your loads. The hybrid inverter sizing calculator in our Inverters & Equipment section can help you size it for the biggest appliance you run.
Why zero-sun sizing tends to overstate what you actually need
A pure battery-only autonomy calculation, useful as a worst-case sanity check, assumes the panels contribute nothing at all during the outage period. In practice, even a dark, overcast sky produces some usable output, typically estimated at 10% to 20% of clear-sky production for planning purposes. Crediting this partial output against your daily load lowers the net deficit the battery actually has to cover, which is the core difference this tool makes versus the simpler battery only autonomy calculator. Once you have that number, the federal ITC calculator shows what it means for the rest of the system. If you want to check this estimate against a second method, the solar panel calculator in our System Sizing section works from your daily load and peak sun hours.
Choosing a conservative cloudy production percentage
10% is a conservative assumption suited to very heavy, sustained overcast or storm conditions, while 20% fits more moderate cloud cover that still lets meaningful diffuse light through. Choosing too optimistic a percentage risks undersizing your battery for a genuinely bad stretch of weather, so when in doubt, lean toward the lower end of this range, especially for systems with limited generator backup.
Pairing this with a generator backup
Rather than sizing the battery bank for an absolute worst-case zero-production scenario that may rarely or never occur, many off-grid builders size around a realistic partial-cloud target like this one and add a generator backup to cover anything beyond it. This combination typically costs less overall than an oversized battery bank built purely around a worst-case assumption. DOE's overview of battery and energy storage technology is a useful primer on how these sizing trade-offs are typically framed.
What to check once you have a battery size
Compare this result against the cloudy day reserve calculator for a related look at short-term reserve planning, and run the battery bank sizing calculator to convert this into a real unit count for your chosen battery size. If you want to see this same trade-off from the battery-count side rather than the day-count side, the battery count vs autonomy tool in our battery storage tools runs it the other direction. Battery cost trends referenced throughout draw on NREL's Storage Futures Study, and a larger bank may also qualify for a tax credit worth checking through the federal ITC calculator in our rebates and incentives tools.
Questions
Frequently asked
A pure battery-only calculation assumes zero solar input during an outage, which overstates the battery size needed since even heavy cloud cover still produces some panel output. This tool credits that partial production, typically 10% to 20% of normal output, giving a more realistic and often smaller battery target for the same autonomy days.
For a system with 800 watts of panel and a 2,000Wh daily load targeting 3 days of autonomy, crediting 15% cloudy production reduces the required battery from about 312Ah to roughly 237Ah, a meaningful reduction in cost and physical space.
10% to 20% of normal clear-sky output is a common planning range for heavy, sustained overcast conditions. Extremely dark storm conditions can dip lower, while lighter cloud cover often still produces 30% or more, so this is a conservative planning assumption rather than a guarantee.
Many off-grid builders pair a realistic partial-cloud sizing target like this one with a generator backup for the rare true zero-production event, rather than sizing the battery bank for a worst case that may never actually happen.